Compare commits
2
Commits
14f8706198
...
1ec485701a
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
1ec485701a | ||
|
|
fbc92d57ba |
@@ -480,3 +480,6 @@ $RECYCLE.BIN/
|
|||||||
|
|
||||||
# Vim temporary swap files
|
# Vim temporary swap files
|
||||||
*.swp
|
*.swp
|
||||||
|
|
||||||
|
# ClickOnce publish profiles are config, not secrets — keep them tracked
|
||||||
|
!TuneBossPC/Properties/PublishProfiles/*.pubxml
|
||||||
@@ -83,6 +83,7 @@ public sealed class SimBleService : IBleService
|
|||||||
BikeManufacturer = 1, // Yamaha
|
BikeManufacturer = 1, // Yamaha
|
||||||
UpgradeLogImmo = 0x0F, // dual-injector unlocked
|
UpgradeLogImmo = 0x0F, // dual-injector unlocked
|
||||||
FirstUseInfo0 = SimTpsCalibrated ? TpsCalibration.CalDoneFlag : (byte)0,
|
FirstUseInfo0 = SimTpsCalibrated ? TpsCalibration.CalDoneFlag : (byte)0,
|
||||||
|
Reg1Reg2 = 1, // activated — so the post-unlock status gate passes offline
|
||||||
});
|
});
|
||||||
|
|
||||||
// ── Auth ──────────────────────────────────────────────────────────────────
|
// ── Auth ──────────────────────────────────────────────────────────────────
|
||||||
|
|||||||
@@ -42,6 +42,18 @@ public sealed class EcuInfo
|
|||||||
public byte UpgradeFuture12 { get; init; }
|
public byte UpgradeFuture12 { get; init; }
|
||||||
public byte UpgradeFuture2 { get; init; } // only if buffer > 68
|
public byte UpgradeFuture2 { get; init; } // only if buffer > 68
|
||||||
|
|
||||||
|
// ── Registration / activation ─────────────────────────────────────────────
|
||||||
|
/// <summary>
|
||||||
|
/// ECU activation nibble (legacy <c>Reg1_Reg2</c> = <c>buf[offset+53] & 0x0F</c>,
|
||||||
|
/// present only on longer info buffers / newer firmware). > 0 means the unit has
|
||||||
|
/// been activated. Used by the post-unlock status gate as the offline / server-error
|
||||||
|
/// fallback and to rescue "not registered" verdicts (see EcuStatusInterpreter).
|
||||||
|
/// </summary>
|
||||||
|
public byte Reg1Reg2 { get; init; }
|
||||||
|
|
||||||
|
/// <summary>True when the ECU reports itself activated (<see cref="Reg1Reg2"/> > 0).</summary>
|
||||||
|
public bool IsActivated => Reg1Reg2 > 0;
|
||||||
|
|
||||||
// ── Derived ──────────────────────────────────────────────────────────────
|
// ── Derived ──────────────────────────────────────────────────────────────
|
||||||
public int RpmLimit => UpgradeRpmMax * 100;
|
public int RpmLimit => UpgradeRpmMax * 100;
|
||||||
/// <summary>
|
/// <summary>
|
||||||
@@ -153,6 +165,13 @@ public sealed class EcuInfo
|
|||||||
hwComp = buf[o + 12];
|
hwComp = buf[o + 12];
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// Registration/activation nibble — legacy Reg1_Reg2 = buf[offset+53] & 0x0F.
|
||||||
|
// The legacy parser maps offset+37 → FW_Version, which is this parser's o, so
|
||||||
|
// Reg1_Reg2 lands at o+16. Only present on longer buffers (legacy gate: len >= 84);
|
||||||
|
// absent on older units → 0 (treated as "not activated", but those are FW < 150
|
||||||
|
// which the status gate passes anyway).
|
||||||
|
byte reg1Reg2 = buf.Length > o + 16 ? (byte)(buf[o + 16] & 0x0F) : (byte)0;
|
||||||
|
|
||||||
var appInfoVersion = buf[^1]; // last byte
|
var appInfoVersion = buf[^1]; // last byte
|
||||||
var pwdRstCount = buf[^5]; // 4 bytes from end
|
var pwdRstCount = buf[^5]; // 4 bytes from end
|
||||||
|
|
||||||
@@ -182,6 +201,7 @@ public sealed class EcuInfo
|
|||||||
UpgradeLogImmo = upgradeLogImmo,
|
UpgradeLogImmo = upgradeLogImmo,
|
||||||
UpgradeFuture12 = upgradeFuture12,
|
UpgradeFuture12 = upgradeFuture12,
|
||||||
UpgradeFuture2 = upgradeFuture2,
|
UpgradeFuture2 = upgradeFuture2,
|
||||||
|
Reg1Reg2 = reg1Reg2,
|
||||||
};
|
};
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
@@ -0,0 +1,153 @@
|
|||||||
|
namespace TuneBoss.Core.Models;
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// What the app should do after the post-unlock server status check.
|
||||||
|
/// Mirrors the Flutter <c>checkEmailStatus</c> gate (doneAfterConnect):
|
||||||
|
/// Pass → continue into the app,
|
||||||
|
/// Warn → continue, but show a warning first,
|
||||||
|
/// Block → show the message, disconnect, do NOT load tables.
|
||||||
|
/// </summary>
|
||||||
|
public enum EcuStatusOutcome
|
||||||
|
{
|
||||||
|
Pass,
|
||||||
|
Warn,
|
||||||
|
Block,
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Result of the post-unlock ECU status check against the TracBoss account server.
|
||||||
|
/// </summary>
|
||||||
|
public sealed record EcuStatusResult(
|
||||||
|
EcuStatusOutcome Outcome,
|
||||||
|
string Message,
|
||||||
|
int? SuccessCode,
|
||||||
|
bool ServerReachable)
|
||||||
|
{
|
||||||
|
public bool IsBlocked => Outcome == EcuStatusOutcome.Block;
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Pure interpretation of the server's <c>success</c> code into an app outcome.
|
||||||
|
/// No HTTP or UI here so it can be unit-tested and reused.
|
||||||
|
///
|
||||||
|
/// Ported from the Flutter app's <c>checkEmailStatus</c> (lib/services/tb_interactor.dart),
|
||||||
|
/// MINUS the ECU activation-bit (reg1Reg2) second chance and the global payment/systemSync
|
||||||
|
/// side effects — those are a later phase. Where the Flutter code relied on reg1Reg2 to
|
||||||
|
/// rescue a "not activated" verdict, this build hard-blocks instead.
|
||||||
|
/// </summary>
|
||||||
|
public static class EcuStatusInterpreter
|
||||||
|
{
|
||||||
|
/// <summary>FW below this is a legacy unit that predates activation — always allowed.</summary>
|
||||||
|
public const int LegacyFwCeiling = 150;
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Interpret a definitive server response. Mirrors the legacy Android app's
|
||||||
|
/// <c>CheckEmailStatus</c> success-code handling, including the ECU activation-bit
|
||||||
|
/// (<paramref name="isActivated"/>) rescue on the "not registered" verdicts (5 and 0).
|
||||||
|
/// </summary>
|
||||||
|
/// <param name="success">The server's <c>success</c> status code.</param>
|
||||||
|
/// <param name="fwVersion">This unit's firmware version (for the legacy-ECU branch).</param>
|
||||||
|
/// <param name="isActivated">ECU self-reported activation (<c>Reg1_Reg2 > 0</c>).</param>
|
||||||
|
/// <param name="serverMessage">Optional human message echoed from the server.</param>
|
||||||
|
public static EcuStatusResult Interpret(int success, byte fwVersion, bool isActivated,
|
||||||
|
string? serverMessage = null)
|
||||||
|
{
|
||||||
|
string msg = string.IsNullOrWhiteSpace(serverMessage) ? "" : serverMessage!.Trim();
|
||||||
|
|
||||||
|
switch (success)
|
||||||
|
{
|
||||||
|
// Registered / global / dealer-bypass — full access.
|
||||||
|
case 1:
|
||||||
|
case 2:
|
||||||
|
case 3:
|
||||||
|
case 8:
|
||||||
|
return new EcuStatusResult(
|
||||||
|
EcuStatusOutcome.Pass,
|
||||||
|
success == 8 ? "Dealer-bypassed ECU — access granted."
|
||||||
|
: "ECU registered — access granted.",
|
||||||
|
success, ServerReachable: true);
|
||||||
|
|
||||||
|
// Activated but not warranty-registered — allowed, with a warning.
|
||||||
|
case 6:
|
||||||
|
case 7:
|
||||||
|
return new EcuStatusResult(
|
||||||
|
EcuStatusOutcome.Warn,
|
||||||
|
"This ECU is activated but not registered for warranty.",
|
||||||
|
success, ServerReachable: true);
|
||||||
|
|
||||||
|
// Phone not registered. Legacy: FW < 150 → pass; else if activated → pass with a
|
||||||
|
// "password change disabled" warning; else block.
|
||||||
|
case 5:
|
||||||
|
if (fwVersion < LegacyFwCeiling)
|
||||||
|
return new EcuStatusResult(EcuStatusOutcome.Pass,
|
||||||
|
"Legacy ECU — access granted.", success, ServerReachable: true);
|
||||||
|
return isActivated
|
||||||
|
? new EcuStatusResult(EcuStatusOutcome.Warn,
|
||||||
|
"This ECU is activated but not registered for warranty. "
|
||||||
|
+ "Password change is disabled.",
|
||||||
|
success, ServerReachable: true)
|
||||||
|
: NotActivated(success);
|
||||||
|
|
||||||
|
// Unregistered. Legacy: FW < 150 → pass; else if activated → pass; else block.
|
||||||
|
case 0:
|
||||||
|
if (fwVersion < LegacyFwCeiling)
|
||||||
|
return new EcuStatusResult(EcuStatusOutcome.Pass,
|
||||||
|
"Legacy ECU — access granted.", success, ServerReachable: true);
|
||||||
|
return isActivated
|
||||||
|
? new EcuStatusResult(EcuStatusOutcome.Pass,
|
||||||
|
"ECU activated — access granted.", success, ServerReachable: true)
|
||||||
|
: NotActivated(success);
|
||||||
|
|
||||||
|
// Account removed — warranty void, but access is allowed.
|
||||||
|
case 9:
|
||||||
|
return new EcuStatusResult(
|
||||||
|
EcuStatusOutcome.Warn,
|
||||||
|
"The account for this ECU has been removed — warranty is void.",
|
||||||
|
success, ServerReachable: true);
|
||||||
|
|
||||||
|
// App out of date (server rejected the request shape).
|
||||||
|
case 98:
|
||||||
|
return new EcuStatusResult(
|
||||||
|
EcuStatusOutcome.Block,
|
||||||
|
"Missing parameter. Please update TuneBoss PC to the latest version.",
|
||||||
|
success, ServerReachable: true);
|
||||||
|
|
||||||
|
default:
|
||||||
|
return new EcuStatusResult(
|
||||||
|
EcuStatusOutcome.Block,
|
||||||
|
$"Unrecognised ECU status from server (code {success})"
|
||||||
|
+ (msg.Length > 0 ? $": {msg}" : "."),
|
||||||
|
success, ServerReachable: true);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Outcome when the server can't be reached (offline, timeout, or a transport/parse error).
|
||||||
|
/// Mirrors the legacy Android offline / server-error fallback exactly: FW < 150 passes,
|
||||||
|
/// an activated ECU (<paramref name="isActivated"/>) passes, and only a genuinely
|
||||||
|
/// unactivated modern unit is blocked. This is why an activated unit still works offline.
|
||||||
|
/// </summary>
|
||||||
|
public static EcuStatusResult Unreachable(byte fwVersion, bool isActivated, string? reason = null)
|
||||||
|
{
|
||||||
|
if (fwVersion < LegacyFwCeiling)
|
||||||
|
return new EcuStatusResult(EcuStatusOutcome.Pass,
|
||||||
|
"Legacy ECU — access granted (server not contacted).", SuccessCode: null,
|
||||||
|
ServerReachable: false);
|
||||||
|
|
||||||
|
if (isActivated)
|
||||||
|
return new EcuStatusResult(EcuStatusOutcome.Pass,
|
||||||
|
"ECU activated — access granted (server not contacted).", SuccessCode: null,
|
||||||
|
ServerReachable: false);
|
||||||
|
|
||||||
|
string why = string.IsNullOrWhiteSpace(reason) ? "" : $" ({reason})";
|
||||||
|
return new EcuStatusResult(EcuStatusOutcome.Block,
|
||||||
|
"This ECU has not been activated, and the activation server could not be reached "
|
||||||
|
+ "to verify it. Please activate the ECU with your dealer." + why,
|
||||||
|
SuccessCode: null, ServerReachable: false);
|
||||||
|
}
|
||||||
|
|
||||||
|
private static EcuStatusResult NotActivated(int success) => new(
|
||||||
|
EcuStatusOutcome.Block,
|
||||||
|
"This ECU has not been activated. Please activate it with your dealer.",
|
||||||
|
success, ServerReachable: true);
|
||||||
|
}
|
||||||
@@ -49,6 +49,15 @@ public sealed record MemoryLayout
|
|||||||
public MemoryRegion Fuel_Angle2D { get; init; } = MemoryRegion.Unavailable;
|
public MemoryRegion Fuel_Angle2D { get; init; } = MemoryRegion.Unavailable;
|
||||||
public MemoryRegion Secondary_Load_Conversion { get; init; } = MemoryRegion.Unavailable;
|
public MemoryRegion Secondary_Load_Conversion { get; init; } = MemoryRegion.Unavailable;
|
||||||
|
|
||||||
|
// ── Acceleration-compensation 2D tables (FW_Version >= 197) ───────────────
|
||||||
|
// 228-byte tables in the MAIN 2D address space (base 2D opcodes — NOT user tables),
|
||||||
|
// at slots 9/10/11 (index × 228): 0x0804 / 0x08E8 / 0x09CC. The firmware allocates
|
||||||
|
// the cyl2 base tables (slots 5-8) on every unit, so accel comp sits at a fixed
|
||||||
|
// 9-11 regardless of cylinder count.
|
||||||
|
public MemoryRegion Accel_Fuel_Comp { get; init; } = MemoryRegion.Unavailable; // 0x0804 (9×228)
|
||||||
|
public MemoryRegion Accel_Spark_Comp { get; init; } = MemoryRegion.Unavailable; // 0x08E8 (10×228)
|
||||||
|
public MemoryRegion Accel_FuelAngle_Comp { get; init; } = MemoryRegion.Unavailable; // 0x09CC (11×228)
|
||||||
|
|
||||||
// ── 2D user-adjustable tables (cyl1) ─────────────────────────────────────
|
// ── 2D user-adjustable tables (cyl1) ─────────────────────────────────────
|
||||||
public MemoryRegion Fuel_PulseWidth_Adjust1 { get; init; } = MemoryRegion.Unavailable;
|
public MemoryRegion Fuel_PulseWidth_Adjust1 { get; init; } = MemoryRegion.Unavailable;
|
||||||
public MemoryRegion Spark_Angle_Adjust1 { get; init; } = MemoryRegion.Unavailable;
|
public MemoryRegion Spark_Angle_Adjust1 { get; init; } = MemoryRegion.Unavailable;
|
||||||
@@ -179,11 +188,14 @@ public sealed record MemoryLayout
|
|||||||
Fuel_PulseWidth_Adjust1_SubTable = R(0x0018, LenSubTable),
|
Fuel_PulseWidth_Adjust1_SubTable = R(0x0018, LenSubTable),
|
||||||
Spark_Angle_Adjust1_SubTable = R(0x0030, LenSubTable),
|
Spark_Angle_Adjust1_SubTable = R(0x0030, LenSubTable),
|
||||||
|
|
||||||
// Cyl2 2D (zero/unavailable for single cylinder)
|
// Cyl2 2D — MAIN space slots 5/6/7/8, matching the firmware's contiguous 2D
|
||||||
Fuel_PulseWidth2 = isTwoCyl ? R(0x063C, Len2DTable) : MemoryRegion.Unavailable,
|
// declaration (0x0474/0x0558/0x063C/0x0720). The memory is allocated on EVERY
|
||||||
AFR_Target2 = isTwoCyl ? R(0x0720, LenAFRTable) : MemoryRegion.Unavailable,
|
// unit; single-cylinder just doesn't access it (gated isTwoCyl for the nav).
|
||||||
Fuel_Angle2D_2 = isTwoCyl ? R(0x0804, Len2DTable) : MemoryRegion.Unavailable,
|
// (Previously mis-mapped to slots 7-10, which then clashed with accel at 9-11.)
|
||||||
Spark_Angle2 = isTwoCyl ? R(0x08E8, Len2DTable) : MemoryRegion.Unavailable,
|
Fuel_PulseWidth2 = isTwoCyl ? R(0x0474, Len2DTable) : MemoryRegion.Unavailable, // idx 5
|
||||||
|
AFR_Target2 = isTwoCyl ? R(0x0558, LenAFRTable) : MemoryRegion.Unavailable, // idx 6
|
||||||
|
Fuel_Angle2D_2 = isTwoCyl ? R(0x063C, Len2DTable) : MemoryRegion.Unavailable, // idx 7
|
||||||
|
Spark_Angle2 = isTwoCyl ? R(0x0720, Len2DTable) : MemoryRegion.Unavailable, // idx 8
|
||||||
Fuel_PulseWidth_Adjust2 = isTwoCyl ? R(0x09CC, Len2DTable) : MemoryRegion.Unavailable,
|
Fuel_PulseWidth_Adjust2 = isTwoCyl ? R(0x09CC, Len2DTable) : MemoryRegion.Unavailable,
|
||||||
Spark_Angle_Adjust2 = isTwoCyl ? R(0x0AB0, Len2DTable) : MemoryRegion.Unavailable,
|
Spark_Angle_Adjust2 = isTwoCyl ? R(0x0AB0, Len2DTable) : MemoryRegion.Unavailable,
|
||||||
|
|
||||||
@@ -191,6 +203,13 @@ public sealed record MemoryLayout
|
|||||||
AFR_Target2_SubTable = isTwoCyl ? R(0x0048, LenSubTable) : MemoryRegion.Unavailable,
|
AFR_Target2_SubTable = isTwoCyl ? R(0x0048, LenSubTable) : MemoryRegion.Unavailable,
|
||||||
Fuel_PulseWidth_Adjust2_SubTable = isTwoCyl ? R(0x0060, LenSubTable) : MemoryRegion.Unavailable,
|
Fuel_PulseWidth_Adjust2_SubTable = isTwoCyl ? R(0x0060, LenSubTable) : MemoryRegion.Unavailable,
|
||||||
Spark_Angle_Adjust2_SubTable = isTwoCyl ? R(0x0078, LenSubTable) : MemoryRegion.Unavailable,
|
Spark_Angle_Adjust2_SubTable = isTwoCyl ? R(0x0078, LenSubTable) : MemoryRegion.Unavailable,
|
||||||
|
// Acceleration-compensation tables — FW >= 197, MAIN 2D space, slots 9/10/11
|
||||||
|
// (index × 228): 0x0804 / 0x08E8 / 0x09CC, right after cyl2 Spark_Angle2 (idx 8).
|
||||||
|
// Present on EVERY unit regardless of cylinder count — the cyl2 slots 5-8 are
|
||||||
|
// always allocated in firmware, so accel sits at a fixed 9-11 (fw-gate only).
|
||||||
|
Accel_Fuel_Comp = fw >= 197 ? R(0x0804, Len2DTable) : MemoryRegion.Unavailable,
|
||||||
|
Accel_Spark_Comp = fw >= 197 ? R(0x08E8, Len2DTable) : MemoryRegion.Unavailable,
|
||||||
|
Accel_FuelAngle_Comp = fw >= 197 ? R(0x09CC, Len2DTable) : MemoryRegion.Unavailable,
|
||||||
|
|
||||||
// Misc core
|
// Misc core
|
||||||
MiscCore = R(0x0000, LenMiscCore),
|
MiscCore = R(0x0000, LenMiscCore),
|
||||||
@@ -228,6 +247,8 @@ public sealed record MemoryLayout
|
|||||||
Spark_Angle_Adjust1 = R(0x00E4, Len2DTable),
|
Spark_Angle_Adjust1 = R(0x00E4, Len2DTable),
|
||||||
Fuel_PulseWidth_Adjust2 = isTwoCyl ? R(0x01C8, Len2DTable) : MemoryRegion.Unavailable,
|
Fuel_PulseWidth_Adjust2 = isTwoCyl ? R(0x01C8, Len2DTable) : MemoryRegion.Unavailable,
|
||||||
Spark_Angle_Adjust2 = isTwoCyl ? R(0x02AC, Len2DTable) : MemoryRegion.Unavailable,
|
Spark_Angle_Adjust2 = isTwoCyl ? R(0x02AC, Len2DTable) : MemoryRegion.Unavailable,
|
||||||
|
// Acceleration-compensation tables are inherited from BuildGen2 (MAIN 2D space,
|
||||||
|
// slots 9/10/11, single-cylinder only) — no GEN3 override needed.
|
||||||
};
|
};
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
@@ -31,6 +31,7 @@ public partial class App : Application
|
|||||||
services.AddSingleton<IBleService, BleManager>();
|
services.AddSingleton<IBleService, BleManager>();
|
||||||
|
|
||||||
services.AddSingleton<IAuthService, AuthService>();
|
services.AddSingleton<IAuthService, AuthService>();
|
||||||
|
services.AddSingleton<IEcuStatusService, EcuStatusService>();
|
||||||
services.AddSingleton<ISettingsService, SettingsService>();
|
services.AddSingleton<ISettingsService, SettingsService>();
|
||||||
services.AddSingleton<ISessionService, SessionService>();
|
services.AddSingleton<ISessionService, SessionService>();
|
||||||
services.AddSingleton<INavigationService, NavigationService>();
|
services.AddSingleton<INavigationService, NavigationService>();
|
||||||
|
|||||||
@@ -0,0 +1,52 @@
|
|||||||
|
<?xml version="1.0" encoding="utf-8"?>
|
||||||
|
<!-- Dealer ClickOnce profile. Identical to ClickOnceProfile.pubxml except:
|
||||||
|
• <Dealer>true</Dealer> → defines the DEALER symbol (hides Config + 1D Tables)
|
||||||
|
• separate InstallUrl → its own update channel (never clobbers the full build)
|
||||||
|
• separate Publish dirs → dealer output doesn't overwrite the full build's
|
||||||
|
• distinct product name → separate shortcut / Add-Remove-Programs entry
|
||||||
|
Publish this profile for the dealer release; publish ClickOnceProfile for the full build. -->
|
||||||
|
<Project>
|
||||||
|
<PropertyGroup>
|
||||||
|
<!-- Turns on the dealer build. -->
|
||||||
|
<Dealer>true</Dealer>
|
||||||
|
<ApplicationRevision>3</ApplicationRevision>
|
||||||
|
<ApplicationVersion>1.0.0.*</ApplicationVersion>
|
||||||
|
<BootstrapperEnabled>True</BootstrapperEnabled>
|
||||||
|
<Configuration>Release</Configuration>
|
||||||
|
<CreateWebPageOnPublish>False</CreateWebPageOnPublish>
|
||||||
|
<GenerateManifests>true</GenerateManifests>
|
||||||
|
<Install>True</Install>
|
||||||
|
<InstallFrom>Web</InstallFrom>
|
||||||
|
<IsRevisionIncremented>True</IsRevisionIncremented>
|
||||||
|
<IsWebBootstrapper>True</IsWebBootstrapper>
|
||||||
|
<MapFileExtensions>True</MapFileExtensions>
|
||||||
|
<OpenBrowserOnPublish>False</OpenBrowserOnPublish>
|
||||||
|
<Platform>Any CPU</Platform>
|
||||||
|
<PublishDir>bin\Release\net9.0-windows10.0.19041.0\app.publish.dealer\</PublishDir>
|
||||||
|
<PublishUrl>bin\publish-dealer\</PublishUrl>
|
||||||
|
<PublishProtocol>ClickOnce</PublishProtocol>
|
||||||
|
<PublishReadyToRun>False</PublishReadyToRun>
|
||||||
|
<PublishSingleFile>False</PublishSingleFile>
|
||||||
|
<SelfContained>False</SelfContained>
|
||||||
|
<SignatureAlgorithm>(none)</SignatureAlgorithm>
|
||||||
|
<SignManifests>False</SignManifests>
|
||||||
|
<SkipPublishVerification>false</SkipPublishVerification>
|
||||||
|
<TargetFramework>net9.0-windows10.0.19041.0</TargetFramework>
|
||||||
|
<UpdateEnabled>False</UpdateEnabled>
|
||||||
|
<UpdateMode>Foreground</UpdateMode>
|
||||||
|
<UpdateRequired>False</UpdateRequired>
|
||||||
|
<WebPageFileName>Publish.html</WebPageFileName>
|
||||||
|
<!-- Separate update channel — dealers pull from here, independent of the full build. -->
|
||||||
|
<InstallUrl>https://app.tracboss.com/pcsoftware2/</InstallUrl>
|
||||||
|
<!-- Distinct friendly name (shortcut / Add-Remove Programs). -->
|
||||||
|
<ProductName>TuneBoss PC (Dealer)</ProductName>
|
||||||
|
<PublisherName>FSR Technology</PublisherName>
|
||||||
|
<History>True|2026-09-29T03:23:50.2255705Z||;True|2026-09-25T11:23:59.2144127+08:00||;True|2026-09-18T17:14:57.5162745+08:00||;</History>
|
||||||
|
</PropertyGroup>
|
||||||
|
<ItemGroup>
|
||||||
|
<BootstrapperPackage Include="Microsoft.NetCore.DesktopRuntime.9.0.x64">
|
||||||
|
<Install>true</Install>
|
||||||
|
<ProductName>.NET Desktop Runtime 9.0.13 (x64)</ProductName>
|
||||||
|
</BootstrapperPackage>
|
||||||
|
</ItemGroup>
|
||||||
|
</Project>
|
||||||
@@ -0,0 +1,41 @@
|
|||||||
|
<?xml version="1.0" encoding="utf-8"?>
|
||||||
|
<!-- https://go.microsoft.com/fwlink/?LinkID=208121. -->
|
||||||
|
<Project>
|
||||||
|
<PropertyGroup>
|
||||||
|
<ApplicationRevision>18</ApplicationRevision>
|
||||||
|
<ApplicationVersion>1.0.0.*</ApplicationVersion>
|
||||||
|
<BootstrapperEnabled>True</BootstrapperEnabled>
|
||||||
|
<Configuration>Release</Configuration>
|
||||||
|
<CreateWebPageOnPublish>False</CreateWebPageOnPublish>
|
||||||
|
<GenerateManifests>true</GenerateManifests>
|
||||||
|
<Install>True</Install>
|
||||||
|
<InstallFrom>Web</InstallFrom>
|
||||||
|
<IsRevisionIncremented>True</IsRevisionIncremented>
|
||||||
|
<IsWebBootstrapper>True</IsWebBootstrapper>
|
||||||
|
<MapFileExtensions>True</MapFileExtensions>
|
||||||
|
<OpenBrowserOnPublish>False</OpenBrowserOnPublish>
|
||||||
|
<Platform>Any CPU</Platform>
|
||||||
|
<PublishDir>bin\Release\net9.0-windows10.0.19041.0\app.publish\</PublishDir>
|
||||||
|
<PublishUrl>bin\publish\</PublishUrl>
|
||||||
|
<PublishProtocol>ClickOnce</PublishProtocol>
|
||||||
|
<PublishReadyToRun>False</PublishReadyToRun>
|
||||||
|
<PublishSingleFile>False</PublishSingleFile>
|
||||||
|
<SelfContained>False</SelfContained>
|
||||||
|
<SignatureAlgorithm>(none)</SignatureAlgorithm>
|
||||||
|
<SignManifests>False</SignManifests>
|
||||||
|
<SkipPublishVerification>false</SkipPublishVerification>
|
||||||
|
<TargetFramework>net9.0-windows10.0.19041.0</TargetFramework>
|
||||||
|
<UpdateEnabled>False</UpdateEnabled>
|
||||||
|
<UpdateMode>Foreground</UpdateMode>
|
||||||
|
<UpdateRequired>False</UpdateRequired>
|
||||||
|
<WebPageFileName>Publish.html</WebPageFileName>
|
||||||
|
<InstallUrl>https://app.tracboss.com/pcsoftware/</InstallUrl>
|
||||||
|
<History>True|2026-09-30T04:11:40.3267188Z||;True|2026-09-29T11:23:31.0586994+08:00||;True|2026-09-02T17:44:24.0999910+08:00||;True|2026-08-21T09:49:53.6754436+08:00||;True|2026-08-17T10:54:22.4563316+08:00||;True|2026-08-13T13:52:37.0281846+08:00||;True|2026-08-12T16:05:14.2705192+08:00||;True|2026-07-31T22:49:14.5869146+08:00||;True|2026-07-31T17:55:20.4616585+08:00||;True|2026-07-31T17:29:14.9984524+08:00||;True|2026-07-29T17:02:38.3012266+08:00||;True|2026-07-29T12:51:45.6990187+08:00||;True|2026-07-27T15:30:28.6055849+08:00||;</History>
|
||||||
|
</PropertyGroup>
|
||||||
|
<ItemGroup>
|
||||||
|
<BootstrapperPackage Include="Microsoft.NetCore.DesktopRuntime.9.0.x64">
|
||||||
|
<Install>true</Install>
|
||||||
|
<ProductName>.NET Desktop Runtime 9.0.13 (x64)</ProductName>
|
||||||
|
</BootstrapperPackage>
|
||||||
|
</ItemGroup>
|
||||||
|
</Project>
|
||||||
@@ -0,0 +1,123 @@
|
|||||||
|
using System.Net.Http;
|
||||||
|
using System.Text;
|
||||||
|
using System.Text.Json;
|
||||||
|
using TuneBoss.Core.Models;
|
||||||
|
|
||||||
|
namespace TuneBossPC.Services;
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Talks to the TracBoss account server to check an ECU's registration/activation status
|
||||||
|
/// after unlock, then maps the reply to an app outcome via <see cref="EcuStatusInterpreter"/>.
|
||||||
|
///
|
||||||
|
/// Endpoint + request shape mirror the Flutter app's <c>checkEmailStatus</c>:
|
||||||
|
/// POST https://apiv3.tracboss.com/account/task
|
||||||
|
/// header Auth-Key: asdwqe123asd.dv2lr14
|
||||||
|
/// body { task:"status", tbid, serialNum, firmware_version, model, make }
|
||||||
|
/// </summary>
|
||||||
|
public sealed class EcuStatusService : IEcuStatusService
|
||||||
|
{
|
||||||
|
private const string Endpoint = "https://apiv3.tracboss.com/account/task";
|
||||||
|
private const string AuthKey = "asdwqe123asd.dv2lr14";
|
||||||
|
private static readonly TimeSpan RequestTimeout = TimeSpan.FromSeconds(5);
|
||||||
|
|
||||||
|
// One reusable client. Per-call timeout is enforced with a linked CTS so a caller's
|
||||||
|
// token still cancels early.
|
||||||
|
private static readonly HttpClient Http = new();
|
||||||
|
|
||||||
|
public async Task<EcuStatusResult> CheckAsync(EcuInfo info, string serialNumber, CancellationToken ct = default)
|
||||||
|
{
|
||||||
|
var payload = new Dictionary<string, object?>
|
||||||
|
{
|
||||||
|
["task"] = "status",
|
||||||
|
["tbid"] = info.UniqueId,
|
||||||
|
["serialNum"] = serialNumber,
|
||||||
|
["firmware_version"] = info.FwVersion,
|
||||||
|
["model"] = info.BikeModel,
|
||||||
|
["make"] = info.BikeManufacturer,
|
||||||
|
};
|
||||||
|
|
||||||
|
string json = JsonSerializer.Serialize(payload);
|
||||||
|
|
||||||
|
using var linked = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||||
|
linked.CancelAfter(RequestTimeout);
|
||||||
|
|
||||||
|
try
|
||||||
|
{
|
||||||
|
using var req = new HttpRequestMessage(HttpMethod.Post, Endpoint)
|
||||||
|
{
|
||||||
|
Content = new StringContent(json, Encoding.UTF8, "application/json"),
|
||||||
|
};
|
||||||
|
req.Headers.TryAddWithoutValidation("Auth-Key", AuthKey);
|
||||||
|
|
||||||
|
using var resp = await Http.SendAsync(req, linked.Token);
|
||||||
|
string body = await resp.Content.ReadAsStringAsync(linked.Token);
|
||||||
|
|
||||||
|
if (!resp.IsSuccessStatusCode)
|
||||||
|
return EcuStatusInterpreter.Unreachable(
|
||||||
|
info.FwVersion, info.IsActivated, $"HTTP {(int)resp.StatusCode}");
|
||||||
|
|
||||||
|
if (!TryParse(body, out int success, out string message))
|
||||||
|
return EcuStatusInterpreter.Unreachable(
|
||||||
|
info.FwVersion, info.IsActivated, "bad server response");
|
||||||
|
|
||||||
|
return EcuStatusInterpreter.Interpret(success, info.FwVersion, info.IsActivated, message);
|
||||||
|
}
|
||||||
|
catch (OperationCanceledException) when (ct.IsCancellationRequested)
|
||||||
|
{
|
||||||
|
// The caller cancelled (e.g. disconnect) — not a server problem; surface as unreachable.
|
||||||
|
return EcuStatusInterpreter.Unreachable(info.FwVersion, info.IsActivated, "cancelled");
|
||||||
|
}
|
||||||
|
catch (OperationCanceledException)
|
||||||
|
{
|
||||||
|
return EcuStatusInterpreter.Unreachable(info.FwVersion, info.IsActivated, "timed out");
|
||||||
|
}
|
||||||
|
catch (HttpRequestException ex)
|
||||||
|
{
|
||||||
|
return EcuStatusInterpreter.Unreachable(info.FwVersion, info.IsActivated, ex.Message);
|
||||||
|
}
|
||||||
|
catch (Exception ex)
|
||||||
|
{
|
||||||
|
return EcuStatusInterpreter.Unreachable(info.FwVersion, info.IsActivated, ex.Message);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Pull the integer <c>success</c> code and optional <c>message</c> out of the JSON body.
|
||||||
|
/// Tolerant of <c>success</c> arriving as a number or a numeric string.
|
||||||
|
/// </summary>
|
||||||
|
private static bool TryParse(string body, out int success, out string message)
|
||||||
|
{
|
||||||
|
success = -1;
|
||||||
|
message = "";
|
||||||
|
if (string.IsNullOrWhiteSpace(body)) return false;
|
||||||
|
|
||||||
|
try
|
||||||
|
{
|
||||||
|
using var doc = JsonDocument.Parse(body);
|
||||||
|
var root = doc.RootElement;
|
||||||
|
if (root.ValueKind != JsonValueKind.Object) return false;
|
||||||
|
|
||||||
|
if (!root.TryGetProperty("success", out var s)) return false;
|
||||||
|
switch (s.ValueKind)
|
||||||
|
{
|
||||||
|
case JsonValueKind.Number when s.TryGetInt32(out int n):
|
||||||
|
success = n;
|
||||||
|
break;
|
||||||
|
case JsonValueKind.String when int.TryParse(s.GetString(), out int sn):
|
||||||
|
success = sn;
|
||||||
|
break;
|
||||||
|
default:
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
|
||||||
|
if (root.TryGetProperty("message", out var m) && m.ValueKind == JsonValueKind.String)
|
||||||
|
message = m.GetString() ?? "";
|
||||||
|
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
catch (JsonException)
|
||||||
|
{
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}
|
||||||
@@ -0,0 +1,19 @@
|
|||||||
|
using TuneBoss.Core.Models;
|
||||||
|
|
||||||
|
namespace TuneBossPC.Services;
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Post-unlock ECU status/registration check against the TracBoss account server.
|
||||||
|
/// Called once, right after a successful password unlock, before the app loads tables.
|
||||||
|
/// </summary>
|
||||||
|
public interface IEcuStatusService
|
||||||
|
{
|
||||||
|
/// <summary>
|
||||||
|
/// Ask the server whether this ECU is registered/activated and return the app outcome.
|
||||||
|
/// Never throws for network problems — a timeout / offline / transport error comes back
|
||||||
|
/// as an <see cref="EcuStatusOutcome"/> via <see cref="EcuStatusInterpreter.Unreachable"/>.
|
||||||
|
/// </summary>
|
||||||
|
/// <param name="info">The connected unit's parsed info (tbid, firmware, bike ids).</param>
|
||||||
|
/// <param name="serialNumber">Unit serial — the advertised BLE name with the "B_" prefix stripped.</param>
|
||||||
|
Task<EcuStatusResult> CheckAsync(EcuInfo info, string serialNumber, CancellationToken ct = default);
|
||||||
|
}
|
||||||
@@ -79,6 +79,13 @@ public sealed class MapTableCodec : IMapTableCodec
|
|||||||
yield return new("Spark_Angle_Adjust2", "User Spark Angle 2", K.TwoD);
|
yield return new("Spark_Angle_Adjust2", "User Spark Angle 2", K.TwoD);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// Acceleration compensation — FW >= 197. Not cylinder-split (single set). On older
|
||||||
|
// firmware the entries are absent from the nav, so Prepare/Serialize/Write all skip
|
||||||
|
// them by the (e == null) guards — no explicit FW check needed here.
|
||||||
|
yield return new("Accel_Fuel_Comp_Table_2D", "Acceleration Fuel Compensation", K.TwoD);
|
||||||
|
yield return new("Accel_Spark_Comp_Table_2D", "Acceleration Spark Compensation", K.TwoD);
|
||||||
|
yield return new("Accel_FuelAngle_Comp_Table_2D", "Acceleration Fuel Angle Compensation", K.TwoD);
|
||||||
|
|
||||||
yield return new("Fuel_PulseWidth_Adjust1_SubTable", "User Fuel Pulse Width 1", K.Sub);
|
yield return new("Fuel_PulseWidth_Adjust1_SubTable", "User Fuel Pulse Width 1", K.Sub);
|
||||||
yield return new("Spark_Angle_Adjust1_SubTable", "User Spark Angle 1", K.Sub);
|
yield return new("Spark_Angle_Adjust1_SubTable", "User Spark Angle 1", K.Sub);
|
||||||
if (cyl >= 2)
|
if (cyl >= 2)
|
||||||
@@ -515,6 +522,9 @@ public sealed class MapTableCodec : IMapTableCodec
|
|||||||
"Base Fuel Injection Angle 1" => "Fuel_Angle2D",
|
"Base Fuel Injection Angle 1" => "Fuel_Angle2D",
|
||||||
"Base Fuel Injection Angle 2" => "Fuel_Angle2D_2",
|
"Base Fuel Injection Angle 2" => "Fuel_Angle2D_2",
|
||||||
"Base MAP Compensation" => "Secondary_Load_Conversion",
|
"Base MAP Compensation" => "Secondary_Load_Conversion",
|
||||||
|
"Acceleration Fuel Compensation" => "Accel_Fuel_Comp_Table_2D",
|
||||||
|
"Acceleration Spark Compensation" => "Accel_Spark_Comp_Table_2D",
|
||||||
|
"Acceleration Fuel Angle Compensation" => "Accel_FuelAngle_Comp_Table_2D",
|
||||||
"User Fuel Pulse Width 1" => "Fuel_PulseWidth_Adjust1",
|
"User Fuel Pulse Width 1" => "Fuel_PulseWidth_Adjust1",
|
||||||
"User Fuel Pulse Width 2" => "Fuel_PulseWidth_Adjust2",
|
"User Fuel Pulse Width 2" => "Fuel_PulseWidth_Adjust2",
|
||||||
"User Spark Angle 1" => "Spark_Angle_Adjust1",
|
"User Spark Angle 1" => "Spark_Angle_Adjust1",
|
||||||
|
|||||||
@@ -14,6 +14,7 @@ public partial class ConnectViewModel : ObservableObject, IDisposable
|
|||||||
private readonly IBleService _ble;
|
private readonly IBleService _ble;
|
||||||
private readonly MainWindowViewModel _mainVm;
|
private readonly MainWindowViewModel _mainVm;
|
||||||
private readonly IAuthService _auth;
|
private readonly IAuthService _auth;
|
||||||
|
private readonly IEcuStatusService _ecuStatus;
|
||||||
private readonly ISessionService _session;
|
private readonly ISessionService _session;
|
||||||
private readonly TuneBossPC.ViewModels.Tables.TuningTablesViewModel _tablesVm;
|
private readonly TuneBossPC.ViewModels.Tables.TuningTablesViewModel _tablesVm;
|
||||||
private readonly TuneBossPC.ViewModels.Tables.OneDimTablesViewModel _oneDimVm;
|
private readonly TuneBossPC.ViewModels.Tables.OneDimTablesViewModel _oneDimVm;
|
||||||
@@ -50,16 +51,18 @@ public partial class ConnectViewModel : ObservableObject, IDisposable
|
|||||||
IBleService ble,
|
IBleService ble,
|
||||||
MainWindowViewModel mainVm,
|
MainWindowViewModel mainVm,
|
||||||
IAuthService auth,
|
IAuthService auth,
|
||||||
|
IEcuStatusService ecuStatus,
|
||||||
ISessionService session,
|
ISessionService session,
|
||||||
TuneBossPC.ViewModels.Tables.TuningTablesViewModel tablesVm,
|
TuneBossPC.ViewModels.Tables.TuningTablesViewModel tablesVm,
|
||||||
TuneBossPC.ViewModels.Tables.OneDimTablesViewModel oneDimVm,
|
TuneBossPC.ViewModels.Tables.OneDimTablesViewModel oneDimVm,
|
||||||
TuneBossPC.ViewModels.Tables.MiscValuesViewModel miscVm,
|
TuneBossPC.ViewModels.Tables.MiscValuesViewModel miscVm,
|
||||||
ISnackbarService snackbar)
|
ISnackbarService snackbar)
|
||||||
{
|
{
|
||||||
_ble = ble;
|
_ble = ble;
|
||||||
_mainVm = mainVm;
|
_mainVm = mainVm;
|
||||||
_auth = auth;
|
_auth = auth;
|
||||||
_session = session;
|
_ecuStatus = ecuStatus;
|
||||||
|
_session = session;
|
||||||
_tablesVm = tablesVm;
|
_tablesVm = tablesVm;
|
||||||
_oneDimVm = oneDimVm;
|
_oneDimVm = oneDimVm;
|
||||||
_miscVm = miscVm;
|
_miscVm = miscVm;
|
||||||
@@ -151,6 +154,28 @@ public partial class ConnectViewModel : ObservableObject, IDisposable
|
|||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// Step 3b — Post-unlock ECU status check (server registration / activation gate).
|
||||||
|
// Mirrors the Flutter app's initAfterUnlock → checkEmailStatus gate: a definitive
|
||||||
|
// "not activated" (or an unreachable server, per policy) blocks entry and
|
||||||
|
// disconnects; "activated but not registered" is allowed with a warning.
|
||||||
|
SetStatus("Checking ECU status…");
|
||||||
|
var status = await _ecuStatus.CheckAsync(_ecuInfo, SerialFromAdvertisedName(SelectedDevice.Name));
|
||||||
|
|
||||||
|
if (status.IsBlocked)
|
||||||
|
{
|
||||||
|
MessageBox.Show(status.Message, "ECU Status",
|
||||||
|
MessageBoxButton.OK, MessageBoxImage.Warning);
|
||||||
|
SetStatus($"Blocked: {status.Message}");
|
||||||
|
await _ble.DisconnectAsync();
|
||||||
|
return;
|
||||||
|
}
|
||||||
|
|
||||||
|
if (status.Outcome == TuneBoss.Core.Models.EcuStatusOutcome.Warn)
|
||||||
|
{
|
||||||
|
MessageBox.Show(status.Message, "ECU Status",
|
||||||
|
MessageBoxButton.OK, MessageBoxImage.Warning);
|
||||||
|
}
|
||||||
|
|
||||||
// Step 4 — Populate UI
|
// Step 4 — Populate UI
|
||||||
EcuUsername = _ecuInfo.Username;
|
EcuUsername = _ecuInfo.Username;
|
||||||
EcuFwVersion = $"v{_ecuInfo.FwVersion} FW2: {_ecuInfo.FwVersion2}.{_ecuInfo.FwSubVersion2}";
|
EcuFwVersion = $"v{_ecuInfo.FwVersion} FW2: {_ecuInfo.FwVersion2}.{_ecuInfo.FwSubVersion2}";
|
||||||
@@ -243,6 +268,18 @@ public partial class ConnectViewModel : ObservableObject, IDisposable
|
|||||||
SetStatus("Disconnected");
|
SetStatus("Disconnected");
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// The unit serial the status server expects: the advertised BLE name with the
|
||||||
|
/// leading "B_" prefix stripped (e.g. "B_TBYA028A0498" → "TBYA028A0498").
|
||||||
|
/// </summary>
|
||||||
|
private static string SerialFromAdvertisedName(string advertisedName)
|
||||||
|
{
|
||||||
|
if (string.IsNullOrEmpty(advertisedName)) return string.Empty;
|
||||||
|
return advertisedName.StartsWith("B_", StringComparison.OrdinalIgnoreCase)
|
||||||
|
? advertisedName[2..]
|
||||||
|
: advertisedName;
|
||||||
|
}
|
||||||
|
|
||||||
private void SetStatus(string msg)
|
private void SetStatus(string msg)
|
||||||
{
|
{
|
||||||
StatusMessage = msg;
|
StatusMessage = msg;
|
||||||
|
|||||||
@@ -138,9 +138,17 @@ public partial class DiagnosticsStripViewModel : ObservableObject, IDisposable
|
|||||||
{
|
{
|
||||||
private readonly IBleService _ble;
|
private readonly IBleService _ble;
|
||||||
private IDisposable? _diagSub;
|
private IDisposable? _diagSub;
|
||||||
|
private IDisposable? _connSub;
|
||||||
|
|
||||||
[ObservableProperty] private bool _isRunning;
|
[ObservableProperty] private bool _isRunning;
|
||||||
|
|
||||||
|
/// <summary>True only while a device is connected. The START/STOP toggle is gated on
|
||||||
|
/// this so it can't be pressed with no device (which previously crashed the app).</summary>
|
||||||
|
[ObservableProperty]
|
||||||
|
[NotifyCanExecuteChangedFor(nameof(ToggleCommand))]
|
||||||
|
[NotifyCanExecuteChangedFor(nameof(StartCommand))]
|
||||||
|
private bool _isConnected;
|
||||||
|
|
||||||
// The 6 configurable gauge slots
|
// The 6 configurable gauge slots
|
||||||
public ObservableCollection<GaugeSlotViewModel> Slots { get; } = new()
|
public ObservableCollection<GaugeSlotViewModel> Slots { get; } = new()
|
||||||
{
|
{
|
||||||
@@ -159,18 +167,48 @@ public partial class DiagnosticsStripViewModel : ObservableObject, IDisposable
|
|||||||
public DiagnosticsStripViewModel(IBleService ble)
|
public DiagnosticsStripViewModel(IBleService ble)
|
||||||
{
|
{
|
||||||
_ble = ble;
|
_ble = ble;
|
||||||
|
_connSub = ble.ConnectionStateChanged.Subscribe(OnConnectionStateChanged);
|
||||||
|
}
|
||||||
|
|
||||||
|
private void OnConnectionStateChanged(BleConnectionState state)
|
||||||
|
{
|
||||||
|
System.Windows.Application.Current.Dispatcher.Invoke(() =>
|
||||||
|
{
|
||||||
|
IsConnected = state == BleConnectionState.Connected;
|
||||||
|
|
||||||
|
// Link dropped while streaming — reflect the stopped state so the strip
|
||||||
|
// doesn't keep showing stale values or think it's still running.
|
||||||
|
if (!IsConnected && IsRunning)
|
||||||
|
{
|
||||||
|
_diagSub?.Dispose();
|
||||||
|
_diagSub = null;
|
||||||
|
IsRunning = false;
|
||||||
|
foreach (var slot in Slots) slot.Value = "—";
|
||||||
|
}
|
||||||
|
});
|
||||||
}
|
}
|
||||||
|
|
||||||
// ── Start / Stop ──────────────────────────────────────────────────────────
|
// ── Start / Stop ──────────────────────────────────────────────────────────
|
||||||
|
|
||||||
[RelayCommand]
|
/// <summary>Start/Stop can only run with a connected device.</summary>
|
||||||
|
public bool CanToggle => IsConnected;
|
||||||
|
|
||||||
|
[RelayCommand(CanExecute = nameof(CanToggle))]
|
||||||
public async Task StartAsync()
|
public async Task StartAsync()
|
||||||
{
|
{
|
||||||
if (IsRunning) return;
|
if (IsRunning || !IsConnected) return;
|
||||||
await _ble.StartDiagnosticsAsync();
|
try
|
||||||
IsRunning = true;
|
{
|
||||||
|
await _ble.StartDiagnosticsAsync();
|
||||||
_diagSub = _ble.DiagnosticsFrames.Subscribe(OnFrame);
|
IsRunning = true;
|
||||||
|
_diagSub = _ble.DiagnosticsFrames.Subscribe(OnFrame);
|
||||||
|
}
|
||||||
|
catch (Exception ex)
|
||||||
|
{
|
||||||
|
// Never let a start failure (e.g. no device) take down the app.
|
||||||
|
IsRunning = false;
|
||||||
|
System.Diagnostics.Debug.WriteLine($"[STRIP] Start failed: {ex.Message}");
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
[RelayCommand]
|
[RelayCommand]
|
||||||
@@ -210,11 +248,13 @@ public partial class DiagnosticsStripViewModel : ObservableObject, IDisposable
|
|||||||
public void Dispose()
|
public void Dispose()
|
||||||
{
|
{
|
||||||
_diagSub?.Dispose();
|
_diagSub?.Dispose();
|
||||||
|
_connSub?.Dispose();
|
||||||
}
|
}
|
||||||
|
|
||||||
[RelayCommand]
|
[RelayCommand(CanExecute = nameof(CanToggle))]
|
||||||
public async Task ToggleAsync()
|
public async Task ToggleAsync()
|
||||||
{
|
{
|
||||||
|
if (!IsConnected) return;
|
||||||
if (IsRunning)
|
if (IsRunning)
|
||||||
await StopAsync();
|
await StopAsync();
|
||||||
else
|
else
|
||||||
|
|||||||
@@ -370,6 +370,24 @@ public partial class OneDimTablesViewModel : ObservableObject, IDisposable
|
|||||||
finally { IsReading = false; await ResumeDiagnosticsIfLiveAsync(); }
|
finally { IsReading = false; await ResumeDiagnosticsIfLiveAsync(); }
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Forces a fresh BLE re-read of one 1D table by slot (1-based), refreshing the cached
|
||||||
|
/// model and the on-screen grid if that table is selected. Used after TPS calibration,
|
||||||
|
/// which writes the Throttle Position table (slot 6) directly on the device — without
|
||||||
|
/// this, the 1D page would keep showing the copy cached at connect.
|
||||||
|
/// </summary>
|
||||||
|
public async Task RefreshSlotAsync(int slot)
|
||||||
|
{
|
||||||
|
var entry = Groups.SelectMany(g => g.Entries).FirstOrDefault(e => e.Slot == slot);
|
||||||
|
if (entry == null) return;
|
||||||
|
try
|
||||||
|
{
|
||||||
|
if (await ReadEntryAsync(entry) && entry.Table != null && SelectedEntry == entry)
|
||||||
|
Application.Current.Dispatcher.Invoke(() => PopulateGrid(entry.Table));
|
||||||
|
}
|
||||||
|
catch { /* best-effort refresh */ }
|
||||||
|
}
|
||||||
|
|
||||||
/// <summary>Reads all available 1D tables so they're cached for instant viewing. Mirrors the 2D init.</summary>
|
/// <summary>Reads all available 1D tables so they're cached for instant viewing. Mirrors the 2D init.</summary>
|
||||||
public async Task InitializeAllAsync(IProgress<string>? progress = null)
|
public async Task InitializeAllAsync(IProgress<string>? progress = null)
|
||||||
{
|
{
|
||||||
|
|||||||
@@ -320,6 +320,27 @@ public partial class TuningTablesViewModel : ObservableObject, IDisposable
|
|||||||
});
|
});
|
||||||
Groups.Add(stage3);
|
Groups.Add(stage3);
|
||||||
|
|
||||||
|
// ── Acceleration compensation (FW >= 197) ──
|
||||||
|
// Firmware-gated, not stage-gated: the regions are Unavailable below FW 197,
|
||||||
|
// so the entries (and the whole group) only appear when the unit exposes them.
|
||||||
|
// RequiredStage = 1 keeps the group unlocked on any connected stage.
|
||||||
|
var accel = new TableGroupViewModel { Label = "ACCELERATION COMP", RequiredStage = 1 };
|
||||||
|
// MAIN 2D tables (base read/write opcodes) at slots 9/10/11 — not user tables.
|
||||||
|
if (layout?.Accel_Fuel_Comp?.IsAvailable == true)
|
||||||
|
accel.Entries.Add(MakeEntry("Acceleration Fuel Compensation",
|
||||||
|
layout.Accel_Fuel_Comp, TableEntryType.TuningTable,
|
||||||
|
displayName: "Accel Fuel Comp", icon: TableIconKind.Fuel));
|
||||||
|
if (layout?.Accel_Spark_Comp?.IsAvailable == true)
|
||||||
|
accel.Entries.Add(MakeEntry("Acceleration Spark Compensation",
|
||||||
|
layout.Accel_Spark_Comp, TableEntryType.TuningTable,
|
||||||
|
displayName: "Accel Spark Comp", icon: TableIconKind.Spark));
|
||||||
|
if (layout?.Accel_FuelAngle_Comp?.IsAvailable == true)
|
||||||
|
accel.Entries.Add(MakeEntry("Acceleration Fuel Angle Compensation",
|
||||||
|
layout.Accel_FuelAngle_Comp, TableEntryType.TuningTable,
|
||||||
|
displayName: "Accel Angle Comp", icon: TableIconKind.Angle));
|
||||||
|
if (accel.Entries.Count > 0)
|
||||||
|
Groups.Add(accel);
|
||||||
|
|
||||||
// Read-only gate: a group is stage-unlocked if the ECU is at/above its stage.
|
// Read-only gate: a group is stage-unlocked if the ECU is at/above its stage.
|
||||||
// Offline (connectedStage == null) leaves everything unlocked. Entries mirror
|
// Offline (connectedStage == null) leaves everything unlocked. Entries mirror
|
||||||
// their group so per-entry comms gating is a simple bind.
|
// their group so per-entry comms gating is a simple bind.
|
||||||
@@ -422,9 +443,19 @@ public partial class TuningTablesViewModel : ObservableObject, IDisposable
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
else
|
else
|
||||||
|
{
|
||||||
|
// Not loaded — clear the grid so it shows EMPTY, not the previously
|
||||||
|
// selected table's data (that stale carry-over looked like the old
|
||||||
|
// table "reappearing" under the new one). READ will populate it.
|
||||||
|
RpmHeaders.Clear();
|
||||||
|
LoadHeaders.Clear();
|
||||||
|
Rows.Clear();
|
||||||
|
SubRows.Clear();
|
||||||
|
SurfaceChanged?.Invoke();
|
||||||
StatusMessage = entry.IsStandaloneSub
|
StatusMessage = entry.IsStandaloneSub
|
||||||
? "Click READ to load this subtable."
|
? "Click READ to load this subtable."
|
||||||
: "Click READ to load this table.";
|
: "Click READ to load this table.";
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
// ── Read ──────────────────────────────────────────────────────────────────
|
// ── Read ──────────────────────────────────────────────────────────────────
|
||||||
|
|||||||
@@ -25,6 +25,11 @@ public partial class TpsCalViewModel : ObservableObject, IDisposable
|
|||||||
{
|
{
|
||||||
private readonly IBleService _ble;
|
private readonly IBleService _ble;
|
||||||
private readonly ISessionService _session;
|
private readonly ISessionService _session;
|
||||||
|
private readonly TuneBossPC.ViewModels.Tables.OneDimTablesViewModel _oneDim;
|
||||||
|
|
||||||
|
/// <summary>1D slot of the Throttle Position (TPS conversion) table — the one the
|
||||||
|
/// calibration write at 0x0078 lands in, refreshed after a successful cal.</summary>
|
||||||
|
private const int ThrottlePositionSlot = 6;
|
||||||
|
|
||||||
private IDisposable? _diagSub;
|
private IDisposable? _diagSub;
|
||||||
private TpsCalibration.Addresses _addr;
|
private TpsCalibration.Addresses _addr;
|
||||||
@@ -61,10 +66,12 @@ public partial class TpsCalViewModel : ObservableObject, IDisposable
|
|||||||
|
|
||||||
public bool IsIdle => !IsCalibrating && !IsBusy;
|
public bool IsIdle => !IsCalibrating && !IsBusy;
|
||||||
|
|
||||||
public TpsCalViewModel(IBleService ble, ISessionService session)
|
public TpsCalViewModel(IBleService ble, ISessionService session,
|
||||||
|
TuneBossPC.ViewModels.Tables.OneDimTablesViewModel oneDim)
|
||||||
{
|
{
|
||||||
_ble = ble;
|
_ble = ble;
|
||||||
_session = session;
|
_session = session;
|
||||||
|
_oneDim = oneDim;
|
||||||
}
|
}
|
||||||
|
|
||||||
// ── Activation ─────────────────────────────────────────────────────────────
|
// ── Activation ─────────────────────────────────────────────────────────────
|
||||||
@@ -229,6 +236,12 @@ public partial class TpsCalViewModel : ObservableObject, IDisposable
|
|||||||
StatusMessage = fr.Success
|
StatusMessage = fr.Success
|
||||||
? "TPS calibration successful and saved to ECU."
|
? "TPS calibration successful and saved to ECU."
|
||||||
: $"Flash write failed: {fr.ErrorMessage}";
|
: $"Flash write failed: {fr.ErrorMessage}";
|
||||||
|
|
||||||
|
// 4) Refresh the cached Throttle Position 1D table (slot 6, addr 0x0078) that
|
||||||
|
// this calibration just rewrote, so the 1D page reflects the new raw-axis
|
||||||
|
// values instead of the copy cached at connect.
|
||||||
|
if (fr.Success)
|
||||||
|
await _oneDim.RefreshSlotAsync(ThrottlePositionSlot);
|
||||||
}
|
}
|
||||||
catch (Exception ex) { StatusMessage = $"Error during write: {ex.Message}"; }
|
catch (Exception ex) { StatusMessage = $"Error during write: {ex.Message}"; }
|
||||||
finally
|
finally
|
||||||
|
|||||||
Reference in New Issue
Block a user